			 规格  | 
			
			 容量  | 
			
			 电源  | 
			
			 输出  | 
			
			 参考重量  | 
			
			 备注  | 
		|||
| 
			 相数  | 
			
			 (V)  | 
			
			 (A)  | 
			
			 (V)  | 
			
			 (A)  | 
		||||
| 
			 2/220  | 
			
			 2  | 
			
			 1  | 
			
			 220  | 
			
			 50  | 
			
			 0~220  | 
			
			 10  | 
			
			 14  | 
			
			 /  | 
		
| 
			 3/220  | 
			
			 3  | 
			
			 1  | 
			
			 220  | 
			
			 50  | 
			
			 0~220  | 
			
			 15  | 
			
			 16  | 
			
			 /  | 
		
| 
			 5/220  | 
			
			 5  | 
			
			 1  | 
			
			 220  | 
			
			 50  | 
			
			 0~220  | 
			
			 25  | 
			
			 18  | 
			
			 /  | 
		
| 
			 10/220  | 
			
			 10  | 
			
			 1  | 
			
			 220  | 
			
			 50  | 
			
			 0~220  | 
			
			 50  | 
			
			 80  | 
			
			 /  | 
		
| 
			 15/400  | 
			
			 15  | 
			
			 2  | 
			
			 380  | 
			
			 50  | 
			
			 0~430  | 
			
			 37.5  | 
			
			 90  | 
			
			 /  | 
		
| 
			 20/400  | 
			
			 20  | 
			
			 2  | 
			
			 380  | 
			
			 50  | 
			
			 0~430  | 
			
			 50  | 
			
			 100  | 
			
			 /  | 
		
| 
			 25/400  | 
			
			 25  | 
			
			 2  | 
			
			 380  | 
			
			 50  | 
			
			 0~430  | 
			
			 62.5  | 
			
			 120  | 
			
			 /  | 
		
| 
			 30/400  | 
			
			 30  | 
			
			 2  | 
			
			 380  | 
			
			 50  | 
			
			 0~430  | 
			
			 75  | 
			
			 140  | 
			
			 /  | 
		
| 
			 50/400  | 
			
			 50  | 
			
			 2  | 
			
			 380  | 
			
			 50  | 
			
			 0~430  | 
			
			 125  | 
			
			 160  | 
			
			 /  | 
		
| 
			 100/400  | 
			
			 100  | 
			
			 2  | 
			
			 380  | 
			
			 50  | 
			
			 0~430  | 
			
			 250  | 
			
			 50  | 
			
			 调压器外配  | 
		
| 
			 150/3000  | 
			
			 150  | 
			
			 2  | 
			
			 380  | 
			
			 50  | 
			
			 0~430  | 
			
			 50  | 
			
			 50  | 
		|
| 
			 200/3000  | 
			
			 200  | 
			
			 2  | 
			
			 380  | 
			
			 50  | 
			
			 0~430  | 
			
			 65  | 
			
			 50  | 
		|
| 
			 250/3000  | 
			
			 250  | 
			
			 2  | 
			
			 380  | 
			
			 50  | 
			
			 0~430  | 
			
			 84  | 
			
			 50  | 
		|
| 
			 300/3000  | 
			
			 300  | 
			
			 2  | 
			
			 380  | 
			
			 50  | 
			
			 0~430  | 
			
			 100  | 
			
			 50  | 
		|
| 
			 规格  | 
			
			 容量(kVA)  | 
			
			 高压输出电压(kV)  | 
			
			 高压输出电流(mA)  | 
			
			 低压输入  | 
			
			 变比  | 
		|
| 
			 V  | 
			
			 A  | 
		|||||
| 
			 1.5kVA/50kV  | 
			
			 1.5  | 
			
			 50  | 
			
			 30  | 
			
			 200  | 
			
			 7.5  | 
			
			 500  | 
		
| 
			 3kVA/50kV  | 
			
			 3  | 
			
			 50  | 
			
			 60  | 
			
			 200  | 
			
			 15  | 
			
			 500  | 
		
| 
			 5kVA  | 
			
			 5  | 
			
			 50  | 
			
			 100  | 
			
			 200  | 
			
			 25  | 
			
			 500  | 
		
| 
			 5  | 
			
			 100  | 
			
			 50  | 
			
			 200  | 
			
			 1000  | 
		||
| 
			 10kVA  | 
			
			 10  | 
			
			 50  | 
			
			 200  | 
			
			 220/380  | 
			
			 50/26  | 
			
			 500  | 
		
| 
			 10  | 
			
			 100  | 
			
			 100  | 
			
			 200/380  | 
			
			 1000  | 
		||
| 
			 20kVA  | 
			
			 20  | 
			
			 50  | 
			
			 400  | 
			
			 380  | 
			
			 53  | 
			
			 500  | 
		
| 
			 20  | 
			
			 100  | 
			
			 200  | 
			
			 380  | 
			
			 1000  | 
		||
| 
			 20  | 
			
			 150  | 
			
			 133  | 
			
			 380  | 
			
			 1500  | 
		||
| 
			 30kVA  | 
			
			 30  | 
			
			 50  | 
			
			 600  | 
			
			 380  | 
			
			 79  | 
			
			 500  | 
		
| 
			 30  | 
			
			 100  | 
			
			 300  | 
			
			 380  | 
			
			 1000  | 
		||
| 
			 30  | 
			
			 150  | 
			
			 200  | 
			
			 380  | 
			
			 1500  | 
		||
| 
			 30  | 
			
			 200  | 
			
			 150  | 
			
			 380  | 
			
			 2000  | 
		||
| 
			 30  | 
			
			 250  | 
			
			 120  | 
			
			 380  | 
			
			 2500  | 
		||
| 
			 50kVA  | 
			
			 50  | 
			
			 50  | 
			
			 1000  | 
			
			 380  | 
			
			 132  | 
			
			 500  | 
		
| 
			 50  | 
			
			 100  | 
			
			 500  | 
			
			 380  | 
			
			 1000  | 
		||
| 
			 50  | 
			
			 150  | 
			
			 333  | 
			
			 380  | 
			
			 1500  | 
		||
| 
			 50  | 
			
			 200  | 
			
			 250  | 
			
			 380  | 
			
			 2000  | 
		||
| 
			 50  | 
			
			 250  | 
			
			 200  | 
			
			 380  | 
			
			 2500  | 
		||
| 
			 100kVA  | 
			
			 100  | 
			
			 100  | 
			
			 1000  | 
			
			 3000  | 
			
			 33  | 
			
			 1000  | 
		
| 
			 100  | 
			
			 150  | 
			
			 666  | 
			
			 3000  | 
			
			 1500  | 
		||
| 
			 100  | 
			
			 200  | 
			
			 500  | 
			
			 3000  | 
			
			 2000  | 
		||
| 
			 150kVA  | 
			
			 150  | 
			
			 150  | 
			
			 1000  | 
			
			 3000  | 
			
			 50  | 
			
			 1500  | 
		
| 
			 150  | 
			
			 200  | 
			
			 750  | 
			
			 3000  | 
			
			 2000  | 
		||
| 
			 150  | 
			
			 250  | 
			
			 600  | 
			
			 3000  | 
			
			 2500  | 
		||
| 
			 200kVA  | 
			
			 200  | 
			
			 200  | 
			
			 1000  | 
			
			 3000  | 
			
			 66  | 
			
			 2000  | 
		
| 
			 200  | 
			
			 250  | 
			
			 800  | 
			
			 3000  | 
			
			 2500  | 
		||
| 
			 300kVA  | 
			
			 300  | 
			
			 200  | 
			
			 1500  | 
			
			 3000  | 
			
			 100  | 
			
			 2000  | 
		
| 
			 300  | 
			
			 250  | 
			
			 1200  | 
			
			 3000  | 
			
			 
  | 
		||
说明:1. 交直流两用型试验变压器的参数同上表,直流参数中的额定直流电压为交流的1.4倍,额定直流电流为交流电流的0.7倍。
                    2. 可根据用户需要在高压绕组中抽出5 -15kV的中压抽头,供高压电机作交流耐压试验。
                    3. 可定制特殊规格的试验变压器。
快速,果断,准确,周到,彻底,服务质量赢得用户的满意。
Quality of service to win customers satisfaction
1、提供专业的技术咨询服务,帮助用户进行产品选型。一个小时内解决用户的技术问题。
2、提供产品参数,样本,质量保证书,企业简介等资料。
3、提供合理报价。一小时内为用户提供规范的产品报价表。
1、采用全国统一的《工业品买卖合同》与您签订合同和技术协议。
2、自觉遵守合同法的规定,确保合同及技术协议顺利履行。
3、产品出厂前在测试中心进行各项性能的测试检验,向用户提供产品的检测数据试验报告。
1、我们将按照客户的要求提供相关的技术培训和技术资料。
2、产品有质量问题,一个月免费免责包退包换,三年免费保修,终生维护,有合同约定的按合同约定。
3、我们保证在15分钟内进行电话指导,由您自行排除设备的简单故障。